Mineral insulated thermocouple

with connector termination

"DTMTC" range

Mineral insulated thermocouples are widely used for temperature measurement in many applications. To their essential characteristics (sensing element, insulation, protecting sheath and connection) those thermocouples add unique properties such as bending possibilities (to suit any environment) and a wide range of dimensions (from miniaturization to great lengths). The compensated connector termination offers quick and reliable connection.

•    Most common thermocouples types: K, J, T, N, S
•    Other thermocouples on request

New  in  2010

Mineral insulated thermocouple with overmoulded plug

+++  improved resistance to vibrations and shocks
+++  strong and reliable contacts
+++  ergonomic

see our DTMTC7- K datasheet

Temperature range

From -200°C to + 1700°C. More information...

Operational and environment temperatures are two of the main criteria for selecting the diameter and material of the mineral sheath.

Temperature resistance of the main MI cables in neutral atmosphere:

304L & 316L SS: + 700°C
310 (25/20) SS : + 1100°C
Inconel 600 : + 1150°C

Recommended usage temperature depending on thermocouple type and sheath diameter:

 J

 T

 K and N

   0,5 - 1 mm

 260

 260

 700

   1,5 mm

 440

 260

 920

   3  mm

 520

 315

 1070

   6  mm

 720

 370

 1150

 

 Temperature resistance of the connectors :

    • standard : 200°C in continuous use and 250°C peaks
    • high temperature : 420°C continuous use and 540°C peaks

Mechanical data 

Bending diameter must be  ³ 5 x sheath diameter

          Compact mineral insulation (magnesium oxide) allows perfect insulation of the wires whichever shape is given to the thermocouple.

Accuracy

The accuracy depends on the thermocouple wire tolerances as per IEC 584 European standard

Response time
to reach x% of the temperature scale interval (in seconds)

 Ø in mm

 63%

90% 

    >  0,5

 0.4

 0.7

     1

 0.5

0.8 

     1,5

 0.8

 1

     2

 1

 1.5

     3

 1.2

 2.1

     4,5

 2.3

4.3 

     6

 3.5

 7

     8

 8.1

 18

Test carried out in compliance with UTE C46-201standard, on a type K thermocouple with ungrounded hot junction, inconel 600 sheath (indicative data)

Applicable standards

  • IEC 584
  • UTE 46201
    Whenever requested by specific applications, other applicable standards are also complied with in compliance with our EMS (Specific calibration Requirements) procedure.

 

The most common dimensions are:

- MI cable diameter "D" : 0.5, 1, 1.5, 2, 3, 4.5, 6, 8 mm

-  "L" sheath length: as per customer request, depending on sheath diameter and type 

 

Recommendation: 
  • immersion length: 10 x MI cable diameter

International colour code for cable and connectors:

 symbol

 +

 -

 Sheath

 JC

 black

 white

 black

 KC

 green

 white

 green

 TC

 brown

 white

 brown

 NC

 pink

 white

 pink

 SC / RC

 orange

 white

 orange

 BC

 grey

 white

 grey

IEC 584-3 standard

Same colour is used for connectors and thermocouples